Pre-launch draft. Clinical pages are awaiting clinical review by the CVICU Compass editorial team. Use for education only. How we review content
CalculatorRhythmFormula checked · awaiting clinical review

QTc calculator (Bazett, Fridericia, Framingham)

Correct the QT interval for heart rate with three formulas, with torsades risk thresholds and a wide-QRS warning.

Results appear here as you type. This tool needs JavaScript; the formula below can be used by hand.

Formula

RR = 60 / HR (s)
Bazett = QT / √RR; Fridericia = QT / ∛RR; Framingham = QT + 154 × (1 − RR)

Worked example

QT 440, HR 96 (RR 0.625): Bazett 557, Fridericia 515, Framingham 498 ms.

Assumptions

  • QT measured in the lead with the longest clear T wave (often II or V5).

Limitations

  • Bazett overcorrects at fast rates and undercorrects at slow rates.
  • Atrial fibrillation: average several beats.

Related

References

  1. Drew BJ, Ackerman MJ, Funk M, et al. Prevention of torsade de pointes in hospital settings: a scientific statement from the AHA and ACCF. Circulation. 2010;121:1047-1060.
  2. Sagie A, Larson MG, Goldberg RJ, et al. An improved method for adjusting the QT interval for heart rate (the Framingham Heart Study). Am J Cardiol. 1992;70:797-801.

Calculators support education and clinical reasoning. They do not make treatment decisions. Results depend on the accuracy of the values entered and the assumptions listed.